Home Markets Insights Tools Services About Contact Get a Report →
NEM Spot $/MWh
NSW$94.20
VIC$82.50
QLD$108.75
SA$77.30
TAS$68.90
NEM Spot $/MWh
NSW$94.20
VIC$82.50
QLD$108.75
SA$77.30
TAS$68.90

Free Tools

Energy & carbon calculators

Practical, free tools to help you understand your energy costs and emissions on a like-for-like basis. Pick a tool below to get started.

Choose a calculator

Fuel Cost & Carbon Comparator

Compare what you pay across fuels, cost and emissions, side by side

Prefill region

Enter what you pay for any fuels below, or prefill with current market prices for your region. Everything converts to a common $/GJ basis so you can see the true cost of delivered energy, alongside the carbon emissions of each.

Annual energy use (optional): GJ per year, adds an annual cost to each fuel and the ranking below
Electricity
Price (c/kWh)
Cost $/GJ
kg CO₂-e/GJ
Annual $
Natural Gas
Price ($/GJ)
Cost $/GJ
kg CO₂-e/GJ
Annual $
Diesel
Price (c/L)
Cost $/GJ
kg CO₂-e/GJ
Annual $
LPG
Price (c/L)
Cost $/GJ
kg CO₂-e/GJ
Annual $
Coal (thermal)
Price ($/tonne)
Cost $/GJ
kg CO₂-e/GJ
Annual $

Cost ranking ($/GJ, lower is cheaper)

Enter at least one price to compare.

Carbon ranking (kg CO₂-e/GJ, lower is cleaner)

Enter at least one price to compare.

EnergyDesk Insight

Conversions use NGA energy content factors (electricity 3.6 MJ/kWh, diesel 38.6 MJ/L, LPG 25.7 MJ/L, coal ≈ 27 GJ/tonne) and combustion emissions factors (gas 51.4, LPG 60.2, diesel 70.2, coal 90.2 kg CO₂-e/GJ; electricity uses an indicative grid Scope 2 factor of 68 kg CO₂-e/GJ). Indicative only. For a tailored analysis, request a custom report →. Factors per the National Greenhouse Accounts ↗.

Carbon Emissions Calculator

Estimate your annual Scope 1 & 2 emissions from energy use

Enter your annual consumption for each fuel you use. The calculator applies NGA emissions factors to estimate your total annual emissions in tonnes of CO₂-e.

Electricity
kWh / year
t CO₂-e/yr
Natural Gas
GJ / year
t CO₂-e/yr
Diesel
Litres / year
t CO₂-e/yr
LPG
Litres / year
t CO₂-e/yr

Estimated total annual emissions

0.0 t CO₂-e

Emissions factors: electricity Scope 2 ≈ 0.68 kg CO₂-e/kWh (national indicative, varies by state), gas 51.4 kg/GJ, diesel 2.71 kg/L, LPG 1.55 kg/L. Indicative only and not a substitute for formal NGER reporting. Factors per the National Greenhouse Accounts ↗.

Energy Unit Converter

Convert between common energy units instantly

Enter a value and choose its unit, the equivalent in all other common energy units is shown below. Useful for reconciling bills, contracts and equipment specs that use different units.

Choose the unit your value is in

Standard energy conversions. 1 kWh = 3.6 MJ · 1 GJ = 1000 MJ · 1 therm = 105.5 MJ · 1 MMBtu = 1055.06 MJ.

Steam & Boiler Calculator

Estimate the fuel energy and cost to raise process steam

Estimate the fuel energy needed to generate steam, accounting for boiler efficiency. Enter your steam output, efficiency and (optionally) a fuel price to see running cost.

Steam output
tonnes / hour
Boiler efficiency
% (typ. 80–85)
Operating hours
hours / year
Fuel price (optional)
$/GJ

Estimated fuel requirement

Enter your steam output to calculate.

Assumes a net enthalpy rise of ~2.34 GJ per tonne of steam (saturated steam at low pressure from ~85°C feedwater). Actual figures vary with pressure, feedwater temperature and blowdown. Indicative only.

Solar Offset Estimator

Estimate annual generation, bill savings and payback for a rooftop solar system

A high-level estimate of what a rooftop solar system could generate and save. For indicative guidance only, a detailed assessment should account for your load profile, roof orientation and feed-in tariff.

System size
kW
State
location
Electricity price
c/kWh
Install cost (optional)
$ total

Estimated solar performance

Enter system size and electricity price to calculate.

Generation estimates use indicative annual yields per kW by state (NSW ~1,380 kWh, VIC ~1,250, QLD ~1,500, SA ~1,450, WA ~1,550, TAS ~1,100). Assumes ~80% of generation offsets grid consumption. Indicative only; excludes STCs, feed-in tariffs and degradation.

Fuel Switch Analyser

Model the full cost and emissions impact of switching your boiler, kiln or fleet from one fuel to another, including capital payback and carbon reduction over time.

In development

Bill Benchmark

See how your energy rates stack up against regional market benchmarks for businesses of your size and sector, so you know whether you're overpaying.

In development

Payback Calculator

Work out how quickly an energy-saving investment pays for itself

Enter the upfront cost of an upgrade (LED lighting, a more efficient boiler, insulation, solar, etc.) and the annual saving you expect. The calculator shows simple payback, return on investment and total savings over the equipment's life.

Upfront cost
$ total
Annual saving
$ / year
Equipment life (optional)
years

Payback & return

Enter a cost and annual saving to calculate.

Simple payback ignores discount rates, inflation and maintenance. For a full investment case including these factors, request a custom report →.

Need a deeper analysis?

Our custom reports go beyond the calculators, benchmarking your costs, modelling fuel switches, and mapping your carbon obligations with practical tactics to reduce both.

Get a custom report →